TIFF 6.0 Specification
Final—June 3, 1992
Make
The scanner manufacturer.
Tag
= 271 (10F.H)
Type = ASCII
Manufacturer of the scanner, video digitizer, or other type of equipment used to
generate the image. Synthetic images should not include this field.
See also Model, Software.
MaxSampleValue
The maximum component value used.
Tag
= 281 (119.H)
Type = SHORT
N
= SamplesPerPixel
This field is not to be used to affect the visual appearance of an image when it is
displayed or printed. Nor should this field affect the interpretation of any other
field; it is used only for statistical purposes.
Default is 2**(BitsPerSample) - 1.
MinSampleValue
The minimum component value used.
Tag
= 280 (118.H)
Type = SHORT
N
= SamplesPerPixel
See also MaxSampleValue.
Default is 0.
Model
The scanner model name or number.
Tag
= 272 (110.H)
Type = ASCII
The model name or number of the scanner, video digitizer, or other type of equip-
ment used to generate the image.
See also Make, Software.